Configuring the V-Switch 3000 Management Parameters via LCD

After successfully powering up, the V-Switch 3000 LCD display panel displays:

V-Switch 3000

Status: OK

Using the Enter and arrow buttons, you toggle between LCD screens and input the V-Switch management parameters. The Back and Forward buttons toggle between spaces. The Up and Down buttons scroll between values in a space. Press Esc at any time to escape from a field or return to the previous screen level.

10244

Figure 26. LCD Display Panel and Buttons

The default management port via LCD is Eth1.

STEP 1. TOGGLE TO THE IP CONFIGURE SCREEN

From the main status screen, press Enter. The IP Configuration screen appears.

IP CONFIG

Press Enter again. The IP Config Eth1 Port screen appears.

IP Config

ETH1 Port

Press Enter again. The Insert IP screen appears.

Use the Back and Forward buttons to toggle to the desired interface: mgn or eth1.

STEP 2. ENTER MANAGEMENT PORT IP ADDRESS

Enter the management port IP address using the arrow buttons. The Back and Forward buttons toggle between spaces. The Up and Down buttons scroll between values in a space.

Insert IP

_ _ _._ _ _._ _ _._ _ _

2 1 2.1 9 9.0 4 3.0 4 6

Press Enter to enter the IP address and progress to the IP Mask screen.

STEP 3. ENTER MANAGEMENT PORT IP MASK