Configuring the Storage Ports
If your
Table 12: V Switch Interfaces
Type | Name | Description | Alias | Phys Address |
RS232 | cons | RS232 Management | cons | 000000000000 |
|
| Int |
|
|
ETHERNET | mgmt | Fast Ethernet | mgmt | 000000000000 |
|
| Manage |
|
|
FibreChannel | fc1 | FC MMF | fc1 | 000000000000 |
FibreChannel | fc2 | FC MMF | fc2 | 000000000000 |
SCSI | SCSI1 | SCSI Ultra 3 | SCSI1 | 000000000000 |
SCSI | SCSI2 | SCSI Ultra 3 | SCSI2 | 000000000000 |
ETHERNET | eth1 | Gigabit Ethernet | eth1 | 00081a000110 |
|
| Net |
|
|
ETHERNET | eth2 | Gigabit Ethernet | eth2 | 00081a000111 |
|
| Net |
|
|
ETHERNET | eth3 | Gigabit Ethernet | eth3 | 00081a000112 |
|
| Net |
|
|
Viewing SCSI Storage Ports and Bus IDs
Use the CLI command pscsi show to view all SCSI storage ports and their corresponding SCSI bus ID.
pscsi show
Alias | BusID |
pscsi3 | 12 |
pscsi4 | 7 |
Setting a SCSI Storage Port Bus ID
Each storage port connected to a SCSI device must have a SCSI bus ID. Use the CLI command pscsi set busid to set a storage port’s SCSI bus ID.
pscsi set busid
You need to define two parameters to set a storage port SCSI bus ID:
Chapter 4: | 57 |