SANRAD V-Switch manual Configuring the Storage Ports, Viewing Scsi Storage Ports and Bus IDs

Models: V-Switch

1 300
Download 300 pages 15.92 Kb
Page 63
Image 63

Configuring the Storage Ports

If your V-Switch configuration contains SCSI devices, you can set the storage port bus ID. If your V-Switch configuration contains FC storage ports, you can change the default configuration of each port. Use the CLI command interface show to show all storage port connections.

Table 12: V Switch Interfaces

Type

Name

Description

Alias

Phys Address

RS232

cons

RS232 Management

cons

000000000000

 

 

Int

 

 

ETHERNET

mgmt

Fast Ethernet

mgmt

000000000000

 

 

Manage

 

 

FibreChannel

fc1

FC MMF

fc1

000000000000

FibreChannel

fc2

FC MMF

fc2

000000000000

SCSI

SCSI1

SCSI Ultra 3

SCSI1

000000000000

SCSI

SCSI2

SCSI Ultra 3

SCSI2

000000000000

ETHERNET

eth1

Gigabit Ethernet

eth1

00081a000110

 

 

Net

 

 

ETHERNET

eth2

Gigabit Ethernet

eth2

00081a000111

 

 

Net

 

 

ETHERNET

eth3

Gigabit Ethernet

eth3

00081a000112

 

 

Net

 

 

Viewing SCSI Storage Ports and Bus IDs

Use the CLI command pscsi show to view all SCSI storage ports and their corresponding SCSI bus ID.

pscsi show

Alias

BusID

pscsi3

12

pscsi4

7

Setting a SCSI Storage Port Bus ID

Each storage port connected to a SCSI device must have a SCSI bus ID. Use the CLI command pscsi set busid to set a storage port’s SCSI bus ID.

pscsi set busid

You need to define two parameters to set a storage port SCSI bus ID:

Chapter 4: V-Switch Configuration

57

Page 63
Image 63
SANRAD V-Switch Configuring the Storage Ports, Viewing Scsi Storage Ports and Bus IDs, Setting a Scsi Storage Port Bus ID