storage blink activate –s Stor_1 –t 120

Use the CLI command storage blink abort to stop the blinking before the end of the set time.

storage blink abort

You need to define one parameter to stop blinking a storage device:

SWITCH

PARAMETER

DEFINITION

STATUS

EXAMPLE

 

 

 

 

 

-s

STORAGE DEVICE

ALAIS OF DEVICE

MANDATORY

Stor_1

 

 

TO BLINK

 

 

 

 

 

 

 

Once a storage device has been identified, use the CLI command storage set to change the device alias or include helpful information on the device.

storage set

SWITCH

PARAMETER

DEFINITION

STATUS

EXAMPLE

-s

-na

-info

STORAGE ALIAS

STORAGE ALIAS TO

MANDATORY

 

MODIFY

 

NEW ALIAS

NEW ALIAS FOR

OPTIONAL

 

STORAGE

 

INFORMATION

INFORMATION ON

OPTIONAL

 

STORAGE TO SET

 

Stor_1

Disk2JBOD5

save_for_snap shots

Example:

The alias of Stor_1 is changed to Disk2JBOD5 for easier identification and it is noted to save the disk for snapshots.

storage set –s Stor_1 –na Disk2JBOD5 –info save_for_snap shots

The V-Switch supports write cache enabling for increased performance. Use the CLI command storage disk set to enable or disable the write cache.

storage disk set

You need to define two parameters to change a device’s write cache setting:

SWITCH

PARAMETER

DEFINITION

STATUS

EXAMPLE

-d

-wce

DISK

DISK DEVICE

MANDATORY

WRITE CACHE

WRITE CACHE

MANDATORY

ENABLED

FUNCTION

YES OR NO

 

 

Disk2JBOD5

yes

86