STEP 6. SYNCHRONIZE MIRROR

Use the CLI command volume mirror synch to synchronize the new

volume data with its intact mirrored volume, Simple3. Once you execute this command, the new mirrored volume will be fully functional.

volume mirror synch –src Simple3 –dst Simple5

The synchronization is finished when the volume status of Simple5 changes from NeedSync to Exposed.

STEP 7. REMOVE FAILED VOLUME

Use the CLI command volume remove all to remove the non-functional virtual volume from the V-Switch database.

volume remove all –vol Simple4

STEP 8. REMOVE FAILED DISK

Use the CLI command volume storage remove to remove the failed disk from the V-Switch database.

storage remove –s Stor_4

Use the CLI command storage show to view the updated storage disk table.

Table 68:

Failed Storage Disk Removed

 

 

Alias

Entity Name

LUN

Oper. Status

Subdisk

Stor_1

500507606058c90

0

Enabled

entire

Stor_2

2000002037f88fb8

0

Enabled

entire

Stor_3

2000002037c32b1f

0

Enabled

entire

Stor_5

500708206059f880

0

Enabled

entire

Sample Configurations

259

Page 266
Image 266
SANRAD V-Switch Volume mirror synch -src Simple3 -dst Simple5, Volume remove all -vol Simple4, Storage remove -s Stor4