EPL Commands

TT

147

TT

Time Recall & Format Layout

Description Use this command to define the time format and print time data. The TT variable is inserted within a Text or Bar Code command's DATA parameter to print the time.

This command works only in printers equipped with the Real Time Clock (RTC) time and date option.

Syntax TTp1[p2p3][+]

Parameters This table identifies the parameters for this format:

Parameters

Details

 

 

p1, p2, p3 = h, m, or s

These parameters describe the format of the time display.

 

 

At lease one parameter must be supplied.

 

 

Each parameter can be any of the values h, m, or s and are

 

 

described below.

 

 

h = Hours displayed as 2 digits (e.g. 01)

 

 

m = Minutes displayed as 2 digits (e.g. 15)

 

 

s = Seconds displayed as 2 digits (e.g. 00)

 

 

Default Value: h:m:s (power-up default format)

 

 

 

+

= Enable 12 Hour

Appending a + to the end of the command string selects 12

 

clock format

hour clock mode. The times will display with an “AM” or

 

 

“PM” indicator. Default (no +) = 24 hour clock mode

 

 

 

= Separator character

The separator may be any ASCII character value between 032

 

 

and 063. The separator character is printed between the

 

 

results of each of the supplied parameters.

 

 

Example • If the current time is 1:25 p.m.:

 

TTh:m:s+

: 01:25:00PM

 

TTh,m

: 13,25

 

TTh+

: 01 PM

When printing the following:

N

TTh:m:s+

A100,500,0,4,1,2,N,"Current Time: "TT

A100,600,0,4,1,2,N,"+ 1Hr"TT+60

A100,700,0,4,1,2,N,"+ 12hrs: "TT+720

P1

the result will be similar to this:

Current Time : 01:25:35PM

+1Hr : 02:25:35PM

+12Hrs : 01:25:35PM