EPL Commands

UP

157

UP

Codepage & Memory Inquiry/Print

Description This command will cause the printer to print and send the currently selected codepage and memory status to the host through the RS-232 port.

This command also disables software flow control (XON/XOFF). Hardware flow control is not disabled (DTR/CTS). To restart software flow control a reset (^@ command) or power must be recycled.

See also the I, M, U, UI and UM commands.

Syntax UP

The printer will send information about the currently selected code page and memory status back to the host followed by printing the current printer configuration. For an example of the configuration printout, see the U command.

The format of data sent to the host is as follows:

UPp1,p2,p3,p4,p5,p6,p7,p8

Parameters This table identifies the parameters for this format:

Parameters

Details

 

 

p1

Image buffer size in KBytes.

p2

Form memory allocation size in KBytes.

 

 

p3

Form memory free in KBytes.

 

 

p4

Graphic memory allocation size in KBytes.

p5

Graphic memory free in KBytes.

 

 

p6

External font memory allocation size in KBytes.

 

 

p7

External font memory free in KBytes.

p8

Appends a response in the UI command data format. See the

 

UI command on page 154.

Example •

Up↵

12/16/13

EPL Programming Guide

14245L-003 Rev. A

Page 157
Image 157