EPL Commands

AUTOFR

Isolating Data from the Input Device

Place the printer in the diagnostic dump mode and send from your data input device.

All characters the device sends will be printed on the label.

If nothing prints, nothing is arriving; check pin-outs and serial settings.

Disabling AUTOFR

Send a XOFF data character (13 hex. or ASCII 19) or a NUL (00 hex. or ASCII 0) to the printer. The form may now be deleted from the printer.

Important • G-Series printers will only accept a NUL (00 hex. or ASCII 0) character.

51

Removing AUTOFR

The programmer must send a Delete Form - FK command to the printer after disabling

AUTOFR.

FK"AUTOFR"

FK"AUTOFR"

12/16/13

EPL Programming Guide

14245L-003 Rev. A

Page 51