EPL Commands

UT

161

UT

Enable Alternate Error Reporting

Description Use this command to enable the printer’s status alternate reporting feature.

Serial Port

If an error occurs, the printer will send a NACK(0x15), followed by the error number, to the computer.

If no errors occur, the printer will echo ACK(0x6) after last line of the current label has been rasterized.

The printer will send a DLE(0x10) when the label is dispensed.

If paper or ribbon empty occurs, the printer will send, through the serial port, a ”-07”, “Pnnn” where nnn is the number of labels remaining to print. (Same as US1 command)

The UT command (when compared to the US1 command) then adds a "Lyyyyy" to the end, where yyyyy is the number of unprinted raster lines. (07PnnnLyyyyy)

Parallel Port

If an error occurs, the printer will print the error number and the printer’s indicator(s) LED will indicate an error condition. See the individual printer’s user manual for details.

Mobile Printers Only (TR220)

Additionally enables command error reporting via printer’s status indicator. The indicator is turned off by default for this printer only.

Note • The printer’s default setting is disabled error reporting.

If enabled, use the UN command to disable error reporting.

Syntax UT

Parameters There are no parameters for this format.

12/16/13

EPL Programming Guide

14245L-003 Rev. A

Page 161
Image 161
Zebra Technologies 14245L-003 manual Enable Alternate Error Reporting, 161, Syntax UT