240

SGD Wired Commands

internal_wired.ip.gateway

internal_wired.ip.gateway

Description This command instructs the printer to change the internal wired print servers gateway address. For printer support, see SGD Command Support on page 315.

Type getvar; setvar

Important • This setting refers to the gateway address. A set value is ignored if the IP protocol is not set to permanent.

Note • For details on SGD command structure, see Command Structure on page 216.

This table identifies the commands for this format:

Commands

Details

 

 

getvar

This command instructs the printer to respond with the internal wired

 

printer servers gateway address.

 

Format: ! U1 getvar "internal_wired.ip.gateway"

 

 

setvar

This command instructs the printer to change the internal wired printer

 

servers gateway address.

 

Format:

 

! U1 setvar "internal_wired.ip.gateway" "value"

 

Values: Any valid gateway address

 

Default: "0.0.0.0"

 

 

Example • This setvar example shows the value set to "10.3.5.1".

!U1 setvar "internal_wired.ip.gateway" "10.3.5.1"

When the setvar value is set to "10.3.5.1", the getvar result is "10.3.5.1".