Administering the SPA400 and Voice Mail Service

5

 

Configuring a SPA400 for PSTN Access

 

 

 

 

 

line. The call is directed according to the Contact List. Also, in the SPA400 web configuration page, click the Status tab, and then verify that a voltage value appears in the Battery Level section.

SPA400 Administration > Status: Battery Level

NOTE If the battery level is 0 V on a line that you have connected to the PSTN, troubleshoot the phone wiring.

Connect to the SPA9000 administration web server, and choose Admin access with Advanced settings. Click Voice tab > Info. Scroll down to the Line 2 Status section, and verify that the Registration Status is Registered.

STEP 12 Click Save Settings.

NOTE If you are using this SPA400 for voice mail service, continue to “Configuring a SPA400 for Voice Mail Service,” on page112.

Configuring a SPA400 for PSTN Access

Typically, there is no need to change the default settings on the Voice page. Make changes only if a problem is suspected and only after consulting with a service technician from your telephone service provider. It is essential that the settings on your system are compatible with those of the Central Office.

SPA9000 Voice System Administration Guide

111