Cisco Systems SPA9000 Ring and Call Waiting Tone Spec section, Control Timer Values sec section

Models: SPA9000

1 286
Download 286 pages 40.22 Kb
Page 231
Image 231

SPA9000 Field Reference

Voice tab

B

Voice tab > Regional page

Ring and Call Waiting Tone Spec section

Ring Waveform

Waveform for the ringing signal: Sinusoid or Trapezoid.

 

Default: Trapezoid

 

 

Ring Frequency

Frequency of the ringing signal. Valid values are 10–100 (Hz).

 

Default: 0

 

 

Ring Voltage

Ringing voltage. 60–90 (V).

 

Default: 85

 

 

CWT Frequency

Frequency script of the call waiting tone. All distinctive CWTs

 

are based on this tone.

 

Default: 440@-10

 

 

Voice tab > Regional page

Control Timer Values (sec) section

Hook Flash Timer Min

Minimum on-hook time before off-hook qualifies as hook-

 

flash. Less than this the on-hook event is ignored. Range: 0.1–

 

0.4 seconds.

 

Default: .1

 

 

Hook Flash Timer Max

Maximum on-hook time before off-hook qualifies as hook-

 

flash. More than this the on-hook event is treated as on-hook

 

(no hook-flash event). Range: 0.4–1.6 seconds.

 

Default: .9

 

 

Callee On Hook Delay

Phone must be on-hook for at this time in sec before the

 

SPA9000 tears down the current inbound call. It does not

 

apply to outbound calls. Range: 0–255 seconds.

 

Default: 0

 

 

Reorder Delay

Delay after far end hangs up before reorder tone is played. 0

 

= plays immediately, inf = never plays. Range: 0–255

 

seconds.

 

Default: 5

 

 

Call Back Expires

Expiration time in seconds of a call back activation. Range: 0–

 

65535 seconds.

 

Default: 1800

 

 

SPA9000 Voice System Administration Guide

229

Page 231
Image 231
Cisco Systems SPA9000 manual Ring and Call Waiting Tone Spec section, Control Timer Values sec section