Table C–8: Common Architecture Opcodes in Numerical Order (Continued)

Opcode

 

Opcode

 

Opcode

 

16.0A0

ADDT

16.182

MULS/U

16.5A3

DIVT/SU

16.0A1

SUBT

16.183

DIVS/U

16.5A4

CMPTUN/SU

16.0A2

MULT

16.1A0

ADDT/U

16.5A5

CMPTEQ/SU

16.0A3

DIVT

16.1A1

SUBT/U

16.5A6

CMPTLT/SU

16.0A4

CMPTUN

16.1A2

MULT/U

16.5A7

CMPTLE/SU

16.0A5

CMPTEQ

16.1A3

DIVT/U

16.5AC

CVTTS/SU

16.0A6

CMPTLT

16.1AC

CVTTS/U

16.5AF

CVTTQ/SV

16.0A7

CMPTLE

16.1AF

CVTTQ/V

16.5C0

ADDS/SUD

16.0AC

CVTTS

16.1C0

ADDS/UD

16.5C1

SUBS/SUD

16.0AF

CVTTQ

16.1C1

SUBS/UD

16.5C2

MULS/SUD

16.0BC

CVTQS

16.1C2

MULS/UD

16.5C3

DIVS/SUD

16.0BE

CVTQT

16.1C3

DIVS/UD

16.5E0

ADDT/SUD

16.0C0

ADDS/D

16.1E0

ADDT/UD

16.5E1

SUBT/SUD

16.0C1

SUBS/D

16.1E1

SUBT/UD

16.5E2

MULT/SUD

16.0C2

MULS/D

16.1E2

MULT/UD

16.5E3

DIVT/SUD

16.0C3

DIVS/D

16.1E3

DIVT/UD

16.5EC

CVTTS/SUD

16.0E0

ADDT/D

16.1EC

CVTTS/UD

16.5EF

CVTTQ/SVD

16.0E1

SUBT/D

16.1EF

CVTTQ/VD

16.6AC

CVTST/S

16.0E2

MULT/D

16.2AC

CVTST

16.700

ADDS/SUIC

16.0E3

DIVT/D

16.500

ADDS/SUC

16.701

SUBS/SUIC

16.0EC

CVTTS/D

16.501

SUBS/SUC

16.702

MULS/SUIC

16.0EF

CVTTQ/D

16.502

MULS/SUC

16.703

DIVS/SUIC

16.0FC

CVTQS/D

16.503

DIVS/SUC

16.720

ADDT/SUIC

16.0FE

CVTQT/D

16.520

ADDT/SUC

16.721

SUBT/SUIC

16.100

ADDS/UC

16.521

SUBT/SUC

16.722

MULT/SUIC

16.101

SUBS/UC

16.522

MULT/SUC

16.723

DIVT/SUIC

16.102

MULS/UC

16.523

DIVT/SUC

16.72C

CVTTS/SUIC

16.103

DIVS/UC

16.52C

CVTTS/SUC

16.72F

CVTTQ/SVIC

16.120

ADDT/UC

16.52F

CVTTQ/SVC

16.73C

CVTQS/SUIC

16.121

SUBT/UC

16.540

ADDS/SUM

16.73E

CVTQT/SUIC

16.122

MULT/UC

16.541

SUBS/SUM

16.740

ADDS/SUIM

16.123

DIVT/UC

16.542

MULS/SUM

16.741

SUBS/SUIM

16.12C

CVTTS/UC

16.543

DIVS/SUM

16.742

MULS/SUIM

16.12F

CVTTQ/VC

16.560

ADDT/SUM

16.743

DIVS/SUIM

16.140

ADDS/UM

16.561

SUBT/SUM

16.760

ADDT/SUIM

16.141

SUBS/UM

16.562

MULT/SUM

16.761

SUBT/SUIM

16.142

MULS/UM

16.563

DIVT/SUM

16.762

MULT/SUIM

16.143

DIVS/UM

16.56C

CVTTS/SUM

16.763

DIVT/SUIM

16.160

ADDT/UM

16.56F

CVTTQ/SVM

16.76C

CVTTS/SUIM

16.161

SUBT/UM

16.580

ADDS/SU

16.76F

CVTTQ/SVIM

16.162

MULT/UM

16.581

SUBS/SU

16.77C

CVTQS/SUIM

16.163

DIVT/UM

16.582

MULS/SU

16.77E

CVTQT/SUIM

16.16C

CVTTS/UM

16.583

DIVS/SU

16.780

ADDS/SUI

16.16F

CVTTQ/VM

16.5A0

ADDT/SU

16.781

SUBS/SUI

16.180

ADDS/U

16.5A1

SUBT/SU

16.782

MULS/SUI

16.181

SUBS/U

16.5A2

MULT/SU

16.783

DIVS/SUI

C–12Alpha Architecture Handbook

Page 314
Image 314