Table 16. Printer Con®guration Items (continued)

Con®guration Item

Description

Value Options

 

 

 

Fuser Inactivity

This entry sets the time, in hours, of printer inactivity

0 to 9 hours. Default is 1 hour.

Timer

before the fuser is turned off. This saves electrical power

 

 

costs and extends the life of the printer. The fuser

 

 

automatically turns on when printing resumes, with a

 

 

delay until the fuser has reached operating temperature.

 

 

A value of 0 means that the timer is not used.

 

Eject to Front Facing

This entry allows accepting or rejecting the Eject to Front

Yes or No

 

Facing (EFF) signals sent by the host. A No value will

 

 

suppress EFFs. If Yes, the EFF signal from the host will

 

 

cause a blank page to be inserted between print jobs if

 

 

the prior job contained an odd number of pages.

 

 

This option should be set to No if either a postprocessing

 

 

device is installed that bursts and stacks output pages, or

 

 

if Direct Attach is set to Yes.

 

 

 

 

Form De®nition

When selected, the form de®nitions are listed in the order

Yes or No

Order

that they were entered.

 

 

 

 

Stacker Enabled

This entry allows setting of whether or not the stacker is

Yes or No

 

to be used. A setting of Yes implies that a postprocessing

 

 

device is not being used and that fanfold forms (not

 

 

roll-feed forms) are being used.

 

 

However, if a postprocessing device is installed and

 

 

enabled, a Yes value is ignored.

 

 

In duplex mode, it refers only to the Printer 2 stacker. In

 

 

dual simplex mode, it may refer to either Printer 1 or

 

 

Printer 2.

 

 

 

 

Chapter 8. Con®guring the System 225

Page 257
Image 257
IBM 3000 manual Conguration Item Description Value Options