FDDI TCP/IP Attachment Information

Table 21 lists all con®guration items, what each item is used for, and the allowable value options for each item. The factory-set default values are underlined.

Table 21. FDDI TCP/IP Attachment Items

Con®guration Item

Description

Value Options

 

 

 

FDDI TCP/IP

Speci®es if the FDDI adapter is installed.

Yes or No

Installed

 

 

 

 

 

TCP Port

Speci®es the TCP socket address of the attachment.

5001 to 65536.

 

Notes:

 

 

1. Only one address is required for operating a simplex

 

 

system.

 

 

2. If your installation runs in dual simplex and duplex

 

 

mode, specify the same TCP Port value for duplex

 

 

mode as you do for Printer 1 in dual simplex mode.

 

 

(IBM recommends using the default value of 5001.)

 

 

Also, make sure you specify a unique value for

 

 

Printer 2 in simplex mode; Printer 1 and Printer 2

 

 

cannot use the same value. (If you use the default

 

 

value of 5001, for Printer 1, IBM recommends using

 

 

5002 as the value for Printer 2.)

 

 

3. The TCP Port numbers speci®ed in the printer

 

 

con®guration must match the PORT numbers

 

 

assigned in the host PSF system.

 

 

4. Because Printer 1 in a dual simplex system and the

 

 

complete system in duplex system share a common

 

 

port number, operational procedures must be de®ned

 

 

to distinguish between duplex and dual simplex

 

 

printing. The easiest way to manage this is to assign

 

 

separate queues for duplex versus dual simplex

 

 

output (for PSF/2 and PSF/6000), and to assign at

 

 

least a unique job class for duplex jobs (for S/390 host

 

 

PSF systems).

 

IP Address

Speci®es the Internet protocol (IP) address of the printer

X.X.X.X where X ≤ 255.

 

in dotted decimal format. Get this value from your LAN

 

 

administrator. This value must match the IP address

 

 

value in the host PSF con®guration.

 

 

This value is unique to a duplex system, and is the same

 

 

regardless of whether the printer is in duplex or

 

 

dual-simplex mode.

 

Subnet Mask

Speci®es the mask that identi®es the local subnet in

X.X.X.X where X ≤ 255

 

dotted decimal format. Get this value from your LAN

 

 

administrator. If you do not have a local subnet, leave

 

 

this ®eld blank.

 

Default Gateway

Speci®es the IP address of the default gateway in dotted

X.X.X.X where X ≤ 255

Address

decimal format. Get this value from your LAN

 

 

administrator.

 

 

 

 

MTU Size

Speci®es the Maximum Transmission Unit (MTU) ±

256 to 4352

 

maximum allowable length of IP packets.

 

 

 

 

Hardware address

Speci®es the FDDI adapter ROM address.

This address cannot be changed.

Chapter 8. Con®guring the System 239