Setting the Preheat Platen Temperature:
The Preheat selection in the Forms Characteristics box allows you to adjust the temperature of the preheat platen for optimum fusing of different types of forms, such as labels or
If you are de®ning a form that requires a preheat platen temperature above or below 80°C, you can enter another temperature in increments of 5°; that is, you can enter temperatures such as 70°, 75°, 85° or 90°C. The minimum temperature you can set is 45°C; the maximum temperature you can set is 100°C.
Operate | Configure | Analyze | Options | Help |
Printer Status
Define Forms
Select a Form Name
Letter
Standard 2UpLetter 12x18
Search...
Width |
12.00 |
Length |
8.50 |
Unit
in. mm
Form Description
Standard 8.5 x 12 in.
Form Characteristics
Pinless: No
Pinless mark: Preprinted form
Printable width: Normal width
Preheat: 0
OK
New Form...
Delete
Cancel
Help
Ready | Check Reset | NPRO | Cancel Job |
HC6OG082
d.To set or change the preheat platen temperature, do the following: v SELECT the Preheat ®eld. A keypad window appears.
v To use the default temperature, enter 0 (zero) on the keypad and SELECT the OK pushbutton.
Note: The default temperature is set under the Con®gure Printer menu.
vTo use a different temperature, enter a number between 45 and 100°C in increments of 5 degrees (for example, 50, 55 or 60). SELECT the OK pushbutton.
e.When you ®nish making all changes to forms, SELECT the OK pushbutton on the De®ne Forms window.