Following the automatic reprinting of pages, you must check for and discard any duplicate pages that may have been printed. Locate the ®rst reprinted page, then ®nd that same page in the stacker or a postprocessing device. Discard all pages starting with that page.
In all cases but one, the automatic reprinting of pages recovers all pages that might have been lost or damaged as the result of the jam. The exception occurs when a FUSER WRAP 0134 jam type is detected. A jam of this type can backup
Also, if automatic reprinting is not allowed, you need to work with the host system console operator to recover lost pages by one of the following actions:
vRestart the job at the point where the output was lost
vRestart the entire job.
Similar to recovering from a forms jam in simplex mode, you must rethread the printer with the jam. However, in addition to rethreading the printer with the jam, you may also have to rethread the other printer (if the jam occurred in Printer 1). Whenever rethreading is required, the Thread/Align Forms Display Touch Screen procedure window automatically appears and requires you to execute and complete that procedure (see ªThread/Align Formsº on page 152).
Important
To clear the jam message from the Display Touch Screen window, the printer logic requires the following:
vFor STACKER JAM 161 and STACKER JAM 164, open and close the stacker gate, or you must lower and then raise the stacker table.
vPress the Check Reset pushbutton on the Display Touch Screen.