3 POSITIONING DEDICATED SIGNALS

(1) Connect/disconnect (D9112)..................................... Command device/Monitor device

This function is used to connect/disconnect the SSCNET communication temporarily, when the servo amplifiers or SSCNET cables on the SSCNET system are exchanged during power supply on of the Motion CPU. The user side requires to connect/disconnect for a system, and the system side stores the states of command accept waiting or execute waiting for connect/disconnect. Moreover, also connect the servo amplifiers disconnected with the connect/disconnect device using this device. When turning the power supply OFF/ON for the axis 1 of SSCNET system, there is no necessity for connect/disconnect processing.

0 ………… Connect/disconnect command accept waiting

-1 ……….. Connect/disconnect execute waiting

1 to 32 ….. Disconnect command

-10 ………. Re-connect command

-2 ………... Connect/disconnect execute command

(2)Test mode request error information (D9182, D9183)........... Monitor device

If there are operating axis at a test mode request from a peripheral device, a test mode request error occurs, the test mode request error flag (M9078) turns on, and the during operation/stop data of the each axis are stored.

 

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

D9182

Axis 16

Axis 15

Axis 14

Axis 13

Axis 12

Axis 11

Axis 10

Axis 9

Axis 8

Axis 7

Axis 6

Axis 5

Axis 4

Axis 3

Axis 2

Axis 1

D9183

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis 32

Axis 31

Axis 30

Axis 29

Axis 28

Axis 27

Axis 26

Axis 25

Axis 24

Axis 23

Axis 22

Axis 21

Axis 20

Axis 19

Axis 18

Axis 17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stores the during operation/stop data of each axis

(Note): The range of axis No.1 to 8 is valid in the Q172HCPU.

0

: During stop

1

: During operation

3 - 61