3 POSITIONING DEDICATED SIGNALS

(12)FLS signal (M2411+20n) (Note-1) ...................................Status signal

(a)This signal is controlled by the ON/OFF state for the upper stroke limit switch input (FLS) of the Q172LX/servo amplifier.

Upper stroke limit switch input OFF ...... FLS signal: ON

Upper stroke limit switch input ON ........ FLS signal: OFF

(b)The state for the upper stroke imit switch input (FLS) when the FLS signal is

ON/OFF is shown below. 1) Q172LX use (Note-2)

FLS signal : ON

FLS signal : OFF

 

 

Q172LX

 

 

Q172LX

FLS

 

 

FLS

FLS

 

 

 

 

 

 

 

 

FLS

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

2) Servo amplifier input use (Note-3)

FLS signal : ON

FLS signal : OFF

 

 

MR-J3- B

 

 

MR-J3- B

FLS

 

 

DI1

FLS

 

 

 

 

 

 

 

 

DI1

 

 

 

 

 

 

 

 

 

 

DICOM

 

 

 

 

DICOM

 

 

 

 

 

 

 

 

 

 

 

 

 

(Note-1): Refer to the "Q173HCPU/Q172HCPU Motion controller Programming Manual (COMMON)" for an external signal.

(Note-2): Refer to the "Q173HCPU/Q172HCPU User’s Manual" for a pin configuration.

(Note-3): Refer to the "MR-J3-B Servo Amplifier Instruction Manual" for a pin configuration.

(13)RLS signal (M2412+20n) (Note-1) .................................. Status signal

(a)This signal is controlled by the ON/OFF state for the lower stroke limit switch input (FLS) of the Q172LX/servo amplifier.

Lower stroke limit switch input OFF ...... RLS signal: ON

Lower stroke limit switch input ON ........ RLS signal: OFF

(b)The state of the lower stroke limit switch input (RLS) when the RLS signal is

ON/OFF is shown below. 1) Q172LX use (Note-2)

RLS signal : ON

RLS signal : OFF

 

 

Q172LX

 

 

Q172LX

RLS

RLS

 

 

 

 

RLS

 

 

 

 

RLS

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 - 18