6POSITIONING CONTROL

(7)Errors details at the data setting for manual pulse generator operation are shown below.

Error details

Error processing

Axis set to manual pulse generator

• Duplicated specified axis is ignored.

• First setting manual pulse generator operation is

operation is specified.

executed.

 

 

• Manual pulse generator operation is executed

Axis setting is 4 axes or more

according to valid for 3 axes from the lowest manual

 

pulse generator axis setting register.

All of bit is "0" for the effective axis No.

• Manual pulse generator operation is not executed.

of manual pulse generator axis No.

 

setting register.

 

[Cautions]

(1)The start accept flag turns on for axis during manual pulse generator operation. Positioning control or home position return cannot be started using the Motion CPU or a peripheral device.

Turn off the manual pulse generator enable flag after the manual pulse generator operation end.

(2)The torque limit value is fixed at 300[%] during manual pulse generator operation.

(3)If the manual pulse generator enable flag turns on for the starting axis by positioning control or JOG operation, an error [214] is set to the applicable axis and manual pulse generator input is not enabled. After the axis has been stopped, the turning off to on of the manual pulse generator enable flag becomes valid, the start accept flag turns on by the manual pulse generator input enabled status, and input from the manual pulse generator is input.

 

V

Positioning control

 

 

Manual pulse generator operation

 

 

t

 

 

ON

Manual pulse generator 1 OFF

Enable

enable flag (M2051)

 

Manual pulse generator

Disable

 

 

ON

enable status

OFF

Start accept flag

Input from manual

 

pulse generator is

 

 

 

 

ignored.

(4)If the manual pulse generator enable flag of another manual pulse generator No. turns on for axis during manual pulse generator operation, an error [214] is set to the applicable axis and the input of that manual pulse generator is not enabled.

Turn the manual pulse generator enable flag on again after stopping the manual pulse generator operation which had become input enable previously.

6 - 185