6POSITIONING CONTROL

(3)JOG operation by the JOG operation command (M3202+20n/M3203+20n) is not executed during the test mode using a peripheral devices.

After release of test mode, the JOG operation is executed by turning the JOG operation command off to on.

During test mode (M9075)

JOG operation command

V

JOG operation is impossible

JOG operation

 

 

without turning JOG operation

 

 

 

 

 

 

command off to on

 

 

 

JOG operation is

 

 

 

 

impossible during test

 

 

 

mode (start error)

 

 

 

 

 

 

 

t

 

ON

 

 

 

 

 

 

 

 

OFF

 

 

 

ON

 

 

 

 

OFF

 

 

 

[Program]

Program for JOG operation is shown as the following conditions.

(1) System configuration

JOG operation for Axis 1 and Axis 2.

Motion CPU control module

Q61P

Q02H

Q172H

Q172

QX41

 

CPU

CPU

LX

 

 

 

 

 

 

 

 

 

 

Forward JOG operation command

 

 

 

 

(PX003 : Axis 1, PX005 : Axis 2)

AMP

AMP

AMP

AMP

Reverse JOG operation command

(PX004 : Axis 1, PX006 : Axis 2)

Axis

Axis

Axis

Axis

 

1 M

2 M

3 M

4 M

 

(2)JOG operation conditions

(a)Axis No. ............................. Axis 1, Axis 2

(b)JOG operation speed .............. 100000

(c)JOG operation commands

1)Forward JOG operation ....... Axis 1: PX003 ON, Axis 2: PX005 ON

2)Reverse JOG operation ...... Axis 1: PX004 ON, Axis 2: PX006 ON

6 - 177