3 POSITIONING DEDICATED SIGNALS

(b)An in-position check is performed in the following cases.

When the servo power supply is turned on.

After the automatic deceleration is started during positioning control.

After the deceleration is started with the JOG start signal OFF.

During the manual pulse generator operation.

After the proximity dog ON during a home position return.

After the deceleration is started with the stop command.

When the speed change to a speed "0" is executed.

(4)Command in-position signal (M2403+20n) .................Status signal

(a)This signal turns on when the absolute value of difference between the command position and feed current value becomes below the "command in-position range" set in the fixed parameters.

This signal turns off in the following cases.

Positioning control start

Home position return

Speed control

JOG operation

Manual pulse generator operation

(b)Command in-position check is continually executed during position control. This check is not executed during speed control or speed control in the speed/position switching control.

(c)

 

 

Switch from speed to position

 

V

 

Command in-position setting

 

Command in-position

 

 

 

Position

Speed/position

 

setting

 

 

 

 

 

 

 

control

 

 

 

 

 

 

control start

 

 

 

 

 

 

start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command in-position ON (M2403+20n)

OFF

 

 

 

 

 

Execution of command in-position check

 

Execution of command

 

 

in-position check

(5)Speed controlling signal (M2404+20n) ........................Status signal

(a)This signal turns on during speed control, and it is used as judgement of during the speed control or position control.

It is turning on while the switching from speed control to position control by the external CHANGE signal at the speed/position switching control.

3 - 14