6 POSITIONING CONTROL

[Program]

Program for restarting after stop during control with the speed/position switching control is shown as the following conditions.

(1) System configuration

Speed/position switching control of Axis 4.

Motion CPU control module

Q61P Q02H Q172H Q172 QX41

CPU CPU LX

Start command (PX000), restart command (PX001), stop command (PX002)

AMP

AMP

AMP

AMP

Axis

Axis

Axis

Axis

1 M

2 M

3 M

4 M

(2)Positioning conditions

(a)Positioning conditions are shown below.

 

 

 

Positioning conditions

 

 

Item

 

Speed/position

 

Restart

 

 

 

 

switching control

 

 

 

 

 

 

 

 

 

 

 

Servo program No.

 

101

 

102

 

 

Control axis

 

Axis 4

 

Axis 4

 

 

Travel value for

 

40000

 

 

 

 

 

 

positioning control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command speed

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

(b)

Positioning start command

...................................

Turning PX000 off to on

 

 

 

 

(OFF

ON)

(c) Speed/position switching enable command .........

M3265

 

 

 

 

(d)

Re-start command .................................................

Turning PX001 off to on

 

 

 

 

(OFF

ON)

(e)

Stop command .....................................................

Turning PX002 off to on

 

 

 

 

(OFF

ON)

6 - 105