4 PARAMETERS FOR POSITIONING CONTROL

4.2.5 Speed control 10multiplier setting for degree axis

The setting range of command speed is 0.001 to 2147483.647[degree/min] normally in the axis of control unit [degree]. However, when the "speed control 10multiplier setting for degree axis" is set to "valid" in the fixed parameter the speed setting range increases 10multiplier "0.01 to 21474836.47[degree/min]".

(1)When the "speed control 10multiplier setting for degree axis" is set to "valid", the positioning control is executed by the speed increased 10multiplier command speed set in the servo program or servo parameter, and speed limit value.

(2)In the interpolation control for the axis of "control unit [degree] and [except degree]", if the interpolation control unit of parameter block is set as [degree]," the positioning control is executed by the speed increased 10multiplier command speed and speed limit value.

(3)When the "speed control 10multiplier setting for degree axis" is set as "valid", 2 figures below the decimal point of ***.** [degree/min] is displayed on the screen of SW6RN-GSVP.

<K 10>

 

 

 

 

 

 

 

 

INC-1

1, 360.00000degree

Axis

Speed

 

180 00degree/min

 

 

 

 

When the "control 10 multiplier

 

 

 

 

 

 

 

 

setting for degree axis" is set to "valid",

 

 

 

 

 

 

 

 

2 figures below the decimal point

 

 

 

 

is displayed .

(4)Speed setting range in the interpolation operation is shown below.

(a)Combined-speed specification/Long-axis speed specification

If the "speed control 10 multiplier setting for degree axis" is set to "valid" even by one axis among interpolation axes, the speed setting range is "0.01 to 21474836.47[degree/min] ".

(b)Reference-axis speed specification

If the "speed control 10 multiplier setting for degree axis" is set to "valid" in the specified reference axis, the speed setting range is "0.01 to 21474836.47[degree/min] ".

4 - 8