6 POSITIONING CONTROL

POINT

Do not set the travel value to "0" for fixed-pitch feed control.

The following results if the travel value is set to "0":

(1)If the travel value of all axes are set to "0", fixed-pitch feed completion without fixed-pitch feed.

[Program]

Program for fixed-pitch feed control using 3 axes linear interpolation is shown as the following conditions.

(1) System configuration

Fixed-pitch feed control using 3 axes linear interpolation of Axis 1, Axis 2 and

Axis 3.

Motion CPU control module

Q61P Q02H Q172H Q172 QX41

CPU CPU LX

Positioning start command (PX000)

AMP

AMP

AMP

AMP

Axis

Axis

Axis

Axis

1 M

2 M

3 M

4 M

(2)Fixed-pitch feed control

(a)Fixed-pitch feed control conditions are shown below.

Item

 

Setting

 

Servo program No.

 

No.320

 

Positioning speed

 

1000

 

Control axes

Axis 1

Axis 2

Axis 3

Travel value

50000

40000

30000

(b)Fixed-pitch feed control start command ....... Turning PX000 off to on (OFF ON)

6 - 86