6 POSITIONING CONTROL

Control using INC-2 (Incremental data method)

(1)Positioning control from the current stop address to the position which combined travel direction and travel value specified with each axis is executed.

(2)The travel direction for each axis is set by the sign (+/ -) of the travel value for each axis, as follows:

Positive travel value .............Positioning control to forward direction (Address increase direction)

Negative travel value............Positioning control to reverse direction (Address decrease direction)

 

Forward direction

(Note-1): Forward: Travel direction for

 

 

 

 

 

 

 

Y1

 

positive travel value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse: Travel direction for

 

 

 

 

 

 

 

 

 

negative travel value

Y-axis travel value

 

 

 

 

 

 

 

: Indicates setting data

Reverse

 

 

 

 

 

 

X1

Current stop address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Forward direction

direction

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-axis travel value

 

 

Reverse

 

 

 

 

 

 

 

 

 

 

direction

 

 

 

 

 

 

Example

When the X-axis travel value is 6000 and Y-axis travel value is -2000.

Home position

 

X-axis travel value

 

 

 

 

(Note-2): Current stop address

 

0

 

 

 

(-1000, -1000)

 

 

 

 

 

 

(Note-2)

 

 

5000

 

Y-axis travel value

 

 

 

 

 

 

 

 

 

 

 

 

Stop position after

 

-3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

positioning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Positioning operation

 

 

 

 

 

 

 

Fig.6.4 Positioning using incremental data method

[Program]

Program for 2 axes linear interpolation control is shown as the following conditions.

(1) System configuration

2 axes linear interpolation control of Axis 3 and Axis 4.

Motion CPU control module

Q61P Q02H Q172H Q172 QX41

CPU CPU LX

Positioning start command (PX000)

AMP AMP AMP AMP

Axis

Axis

Axis

Axis

1 M

2 M

3 M

4 M

6 - 24