APPENDICES

(7) Common device list (Command signal)

Device

Signal name

Refresh cycle

Fetch cycle

Signal direction

Remark

No.

(Note-1), (Note-2)

 

 

 

 

 

M3072

PLC ready flag

 

Main cycle

 

M2000

 

 

 

 

 

 

M3073

Speed switching point designation flag

 

At start

 

M2040

 

 

 

 

 

 

M3074

All axes servo ON command

 

Operation

 

M2042

 

cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At virtual

 

 

M3075

Real/virtual mode change request (SV22)

 

mode

 

M2043

 

 

 

transition

Command

 

 

 

 

 

 

 

JOG operation simultaneous start

 

 

 

M3076

 

 

signal

M2048

command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M3077

Manual pulse generator 1 enable flag

 

 

 

M2051

 

 

 

Main cycle

 

 

M3078

Manual pulse generator 2 enable flag

 

 

M2052

 

 

 

 

 

 

M3079

Manual pulse generator 3 enable flag

 

 

 

M2053

 

 

 

 

 

 

M3080

Motion SFC error history clear request

 

 

 

M2035

flag (Note-3)

 

 

 

M3081

to

Unusable (55 points)

M3135

(Note-1): The device of a remarks column turns ON by OFF to ON of the above device, and the device of a remarks column turns OFF by ON to OFF of the above device. The state of a device is not in agreement when the device of a remarks column is turned on directly. In addition, when the request from a data register and the request from the above device are performed simultaneously, the request from the above device becomes effective.

(Note-2): It can also be ordered the device of a remark column.

(Note-3): M3080 does not turn off automatically. Turn it off as an user side.

(8) Special relay allocated device list (Command signal)

Device

 

Signal name

Refresh cycle

Fetch cycle

Signal direction

Remark

No.

 

(Note-1), (Note-2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M3136

Clock data set request

 

 

 

 

 

 

 

 

 

M9025

 

 

 

 

 

 

 

Main cycle

Command

 

 

 

M3137

Clock data read request

 

 

 

M9028

 

 

 

 

 

 

signal

 

 

 

 

 

 

 

 

 

 

 

 

 

M3138

Error reset

 

 

 

 

 

 

M9060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M3139

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

Unusable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(61 points)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M3199

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Note-1): The device of a remarks column turns ON by OFF to ON of the above device, and the device of a remarks column turns OFF by ON to OFF of the above device. The state of a device is not in agreement when the device of a remarks column is turned on directly.

(Note-2): It can also be ordered the device of a remark column.

APP - 60