6POSITIONING CONTROL

(3)Operation timing and speed-switching positions

Operation timing and speed-switching points for speed-switching control are shown below.

Axis 3 positioning direction

100000

50000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis 2 positioning

V

0

50000

100000

 

150000

200000

direction

50000

0

PLC ready flag (M2000)

All axes servo ON command (M2042)

All axes servo ON accept flag (M2049)

Axis 2 servo ready (M2435) Axis 3 servo ready (M2455) Start command (PX000)

Servo program start

Axis 2 start accept flag (M2002) Axis 3 start accept flag (M2003)

t

6 - 117