APPENDICES

(b)The error detection signal of the erroneous axis turns on at the error occurrence, and the error codes are stored in the minor error code, major error code or servo error code storage register.

Table 1.1 Error code storage registers, error detection signals

Device

 

 

 

 

 

Error code storage register

 

 

 

 

 

Error

 

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

detection

Error class

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

signal

Minor error

D6

D26

D46

D66

D86

D106

D126

D146

D166

D186

D206

D226

D246

D266

D286

D306

M2407+20n

Major error

D7

D27

D47

D67

D87

D107

D127

D147

D167

D187

D207

D227

D247

D267

D287

D307

 

Servo error

D8

D28

D48

D68

D88

D108

D128

D148

D168

D188

D208

D228

D248

D268

D288

D308

M2408+20n

 

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

 

 

 

 

Error code storage register

 

 

 

 

 

Error

 

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

Axis

detection

Error class

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

signal

Minor error

D326

D346

D366

D386

D406

D426

D446

D466

D486

D506

D526

D546

D566

D586

D606

D626

M2407+20n

Major error

D327

D347

D367

D387

D407

D427

D447

D467

D487

D507

D527

D547

D567

D587

D607

D627

 

Servo error

D328

D348

D368

D388

D408

D428

D448

D468

D488

D508

D528

D548

D568

D588

D608

D628

M2408+20n

 

 

 

 

 

 

 

 

 

(Note): The range of axis No. 1 to 8 is valid in the Q172HCPU.

(c)If another error occurs after an error code has been stored, the existing error code is overwritten, deleting it.

However, the error history can be checked using a peripheral device started with the SW6RN-GSVP software.

(d)Error detection signals and error codes are held until the error code reset command (M3207+20n) or servo error reset command (M3208+20n) turns on.

POINTS

(1)Even if the servo error reset (M3208+20n) turns on at the servo error occurrence, the same error code might be stored again.

(2)Reset the servo error after removing the error cause of the servo amplifier side at the servo error occurrence.

APP - 2