APPENDICES

Table 1.2 Servo program setting error list (Continued)

Error code

Error name

 

 

Error contents

Error processing

 

Corrective action

stored in D9190

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary point

(1) The auxiliary point address is

Positioning control does not

(1) If the control unit is

 

setting error

 

outside the setting range at the

start.

[degree], set the auxiliary

 

(At the auxiliary

 

positioning start for absolute data

 

point address within the

 

point-specified

 

method.

 

 

 

range of 0 to 35999999.

 

circular

 

 

 

 

 

 

 

 

n08 (Note)

interpolation. )

 

Unit

Address setting range

 

 

 

 

(At the auxiliary

 

 

0 to

10-5

 

 

 

 

 

point-specified

 

degree

 

 

 

 

 

 

35999999

[degree]

 

 

 

 

 

helical nterpolation.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) The auxiliary point address is set

 

(2) Set the auxiliary point

 

 

 

to -2147483648 (H80000000) at

 

address within the range of

 

 

 

the positioning start for

 

0 to

(231-1).

 

 

 

incremental data method.

 

 

 

 

Radius setting error

(1) The radius is outside the setting

Positioning control does not

(1) If the control unit is

 

(At the radius-

 

range at the positioning control

start.

[degree], set the radius

 

specified circular

 

for absolute data method.

 

within the range of 0 to

 

interpolation.)

 

 

 

 

 

 

35999999.

 

(At the radius-

 

Unit

Address setting range

 

 

 

 

n09 (Note)

specified helical

 

degree

0 to

10-5

 

 

 

 

 

interpolation.)

 

35999999

[degree]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) The radius is set to "0" or

 

(2) Set the radius within the

 

 

 

negative setting at the

 

range of 1 to (231-1).

 

 

 

positioning start for incremental

 

 

 

 

 

 

data method.

 

 

 

 

 

 

Central point setting

(1) The central point address is

Positioning control does not

(1) If the control unit is

 

error

 

outside the setting range at the

start.

[degree], set the central

 

(At the central point-

 

positioning start for absolute data

 

point address within the

 

specified circular

 

method.

 

 

 

range of 0 to 35999999.

 

interpolation.)

 

 

 

 

 

 

 

 

N10 (Note)

(At the central point-

 

Unit

Address setting range

 

 

 

 

specified helical

 

degree

0 to

10-5

 

 

 

 

 

interpolation.)

 

35999999

[degree]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) The central point is set to

 

(2) Set the central point

 

 

 

-2147483648 (H80000000) at

 

address within the range of

 

 

 

the positioning start for

 

0 to

(231-1).

 

 

 

incremental data method.

 

 

 

11

Interpolation control

The interpolation control unit is set

Control with the default

Set the interpolation control

unit setting error

outside the range of 0 to 3.

value "3".

unit within the range of 0 to 3.

 

 

Speed limit value

The speed limit value is set outside

Control with the default

Set the speed limit value within

12

setting error

the setting range.

 

 

value 200000[PLS/s].

the setting range.

 

 

 

 

 

 

 

[For PLS]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to 2147483647[PLS/s]

 

Acceleration time

The acceleration time is set to "0".

Control with the default

Set the acceleration time

 

setting error

 

 

 

 

 

value "1000".

within the range of 1 to 65535.

 

FIN acceleration/

The FIN acceleration/deceleration

 

The FIN acceleration/

13

deceleration setting

time is set except 1 to 5000.

 

deceleration time within the

error

 

 

 

 

 

 

range of 1 to 5000.

 

Fixed position stop

The fixed position stop acceleration/

 

Set the fixed position stop

 

acceleration/

deceleration time is set to "0".

 

acceleration/deceleration time

 

deceleration time

 

 

 

 

 

 

within the range of 1 to 65535.

 

setting error

 

 

 

 

 

 

 

 

14

Deceleration time

The deceleration time is set to "0".

 

Set the deceleration time

setting error

 

 

 

 

 

 

within the range of 1 to 65535.

 

 

 

 

 

 

 

APP - 4