7 AUXILIARY AND APPLIED FUNCTIONS

7.5.1 Cancel/start

When a cancel/start has been set in the setting items of the servo program which was started at the motion control step of the Motion SFC program, the cancel of the running servo program is valid but the servo program specified to start after a cancel is ignored, without being started.

Example of the Motion SFC program which executed control equivalent to a cancel start is shown below.

K0

G0

Selective branch

G1

Providing transition G1 with cancel device condition specified

 

 

 

 

with servo program K0 will cancel to execute of servo program

K1

K0 and allow servo program K1 to start.

 

7 - 11