6POSITIONING CONTROL

(b)Output speed

The output speed is the positioning speed corresponding to the number of pulses input from a manual pulse generator in unit time.

[Output speed] = [Number of input pulses per 1[ms]] [Manual pulse generator 1- pulse input magnification setting]

(3)Setting of the axis operated by the manual pulse generator

The axis operated by the manual pulse generator is set in the manual pulse generator axis setting register (D714 to D719).

The bit corresponding to the axis controlled (1 to 32) is set.

(4)Manual pulse generator 1- pulse input magnification setting

Make magnification setting for 1- pulse input from the manual pulse generator for each axis.

1- pulse input magnification setting register

Applicable axis No. (Note-1)

Setting range

D720

Axis 1

 

D721

Axis 2

 

D722

Axis 3

 

D723

Axis 4

 

D724

Axis 5

 

D725

Axis 6

 

D726

Axis 7

 

D727

Axis 8

 

D728

Axis 9

 

D729

Axis 10

 

D730

Axis 11

 

D731

Axis 12

 

D732

Axis 13

 

D733

Axis 14

 

D734

Axis 15

 

D735

Axis 16

1 to 10000

D736

Axis 17

 

D737

Axis 18

 

D738

Axis 19

 

D739

Axis 20

 

D740

Axis 21

 

D741

Axis 22

 

D742

Axis 23

 

D743

Axis 24

 

D744

Axis 25

 

D745

Axis 26

 

D746

Axis 27

 

D747

Axis 28

 

D748

Axis 29

 

D749

Axis 30

 

D750

Axis 31

 

D751

Axis 32

 

(Note-1): The range of axis No.1 to 8 is valid in the Q172HCPU.

(Note): The manual pulse generator does not have the speed limit value, so they set the magnification setting within the related speed of servomotor.

6 - 183