6 POSITIONING CONTROL

(2)Positioning conditions

(a)Speed control with fixed position stop conditions are shown below.

 

Item

Setting

 

 

 

Servo program No.

55

 

 

 

Start direction

Forward

 

 

 

Control axis

Axis 1

 

 

 

Positioning address

120.00000[degree]

 

 

 

Control speed

30000[degree/min]

 

 

 

Acceleration/deceleration time

20ms

 

 

 

Fixed position stop command device

M100

 

 

(b) Speed control with fixed position stop start command

 

 

............................................................

Turning PX000 off to on (OFF

ON)

(c) Speed control with fixed position stop stop command

 

 

............................................................

Turning PX000 on to off (ON

OFF)

(3) Operation timing

Operation timing for speed control with fixed position stop is shown below.

Stop command of speed control with fixed position stop (PX000 turn on to off)

359.99999[degree]

Current value

 

0[degree]

 

PLC ready flag (M2000)

 

ON

OFF

ON

 

All axes servo ON command

 

(M2042)

OFF

 

All axes servo ON accept flag

OFF

(M2049)

ON

 

120.00000[degree]

20[ms]

Axis 1 servo ready (M2415)

Start command (PX000)

Servo program start

Axis 1 start accept flag (M2001)

Fixed position stop command device (M100)

Positioning complete signal (M2401)

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

ON

ON

Complete signal OFF command

OFF

(M3204)

ON

Command in-position signal

OFF

(M2403)

6 - 168