6POSITIONING CONTROL

(3)Operation timing and speed-switching positions

Operation timing and positions for speed switching are shown below.

Axis 2 positioning direction

40000P4

 

 

 

 

 

 

 

 

P3

 

 

 

 

 

 

 

 

 

20000

 

 

 

 

P2

 

 

 

 

P1

 

Center

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point

 

 

 

 

 

 

 

 

 

 

 

Axis 1 positioning

0

 

 

 

20000

 

40000

 

direction

 

 

 

 

 

V

15000

10000

t

Speed switching point specified flag (M2040)

PLC ready flag (M2000)

All axes servo ON command (M2042)

All axes servo ON accept flag (M2049)

Axis 1 servo ready (M2415)

Axis 2 servo ready (M2435)

Start command (PX000)

Servo program start

Axis 1 start accept flag (M2001)

Axis 2 start accept flag (M2002)