6 POSITIONING CONTROL

[Program]

Program for repetition constant-speed control is shown as the following conditions.

(1) System configuration

Constant-speed control for Axis 2 and Axis 3.

Motion CPU control module

Q61P Q02H Q172H Q172 QX41

CPU CPU LX

Start command (PX000)

AMP AMP AMP AMP

Axis

Axis

Axis

Axis

1 M

2 M

3 M

4 M

(2)Positioning conditions

(a)Constant-speed control conditions are shown below.

Item

Setting

Servo program No.

510

Control axis

Axis 2, Axis 3

Positioning speed

10000

(b)Constant-speed control start command ....... Turning PX000 off to on (OFF ON)

6 - 126