APPENDICES

(5) System errors (900 to 999)Table 1.7 System error (900 to 999) list

 

pitch-Fixedfeed

 

Speed/positionswitching

Control mode

positionHomereturn

followPosition-up control

Positioning

Speed

switchingSpeed

speed-Constant

JOG

pulseManualgenerator

Error

 

 

 

 

 

 

 

 

 

code

 

 

 

 

 

 

 

 

 

901

OSC Speed control with fixed position stop

Error

Error causeCorrective action processing

• The motor travel value while

• Check the position.

the power is off exceeded

• Check the battery of encoder.

the "System setting mode-

Further

allowable travel value during

operation

power off" set in the system

is possible.

settings at the turning on of

 

the servo amplifier.

 

APP - 16