3 POSITIONING DEDICATED SIGNALS

(2)Positioning complete signal (M2401+20n) ..................Status signal

(a)This signal turns on with the completion for the positioning control of the axis specified with the servo program.

It does not turn on at the start or stop on the way using home position return, JOG operation, manual pulse generator operation or speed control. It does not turn on at the stop on the way during positioning.

It can be used to read a M-code at the positioning completion. (Refer to Section 7.1.)

(b)This signal turns off at turning the complete signal OFF command (M3204+20n) off to on or positioning start.

When the complete signal OFF command (M3204+20n) turns off to on.

V

Dwell time

Servo program start

 

 

 

 

t

 

 

 

 

 

 

 

 

Start accept flag

 

ON

 

ON

OFF

 

OFF

(M2001 to M2032)

 

 

 

 

ON

Positioning complete signal

 

 

 

OFF

 

 

 

(M2401+20n)

 

 

 

 

 

 

ON

Complete signal OFF

 

 

 

OFF

 

 

 

command (M3204+20n)

 

 

 

 

 

When the next positioning starts.

 

V

Dwell time

Positioning

Positioning start

 

completion

 

 

 

 

 

 

Servo program start

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

ON

Start accept flag

 

 

ON

 

OFF

 

OFF

 

 

(M2001 to M2032)

 

 

 

 

 

 

ON

 

 

Positioning complete signal

 

 

 

 

 

OFF

 

 

 

 

(M2401+20n)

 

 

 

 

 

 

 

 

 

 

(3)In-position signal (M2402+20n) ...................................Status signal

(a)This signal turns on when the number of droop pulses in the deviation counter becomes below the "in-position range" set in the servo parameters. It turns off at the start.

Number of droop pulses

In-position range

In-position ON (M2402+20n)

t

OFF

3 - 13