6 POSITIONING CONTROL

(3) Operation timing

Operation timing for fixed-pitch feed control using 2 axes linear interpolation is shown below.

VServo program No.310

10000

t

PLC ready flag (M2000)

All axes servo ON command (M2042)

All axes servo ON accept flag (M2049)

Axis 2 servo ready (M2435)

Axis 3 servo ready (M2455)

Start command (PX000)

Servo program start

Axis 2 start accept flag (M2002)

Axis 3 start accept flag (M2003)

(4) Servo program

Servo program No.310 for fixed-pitch feed control using 2 axes linear interpolation is shown below.

<K 310>

 

 

 

 

Fixed-pitch feed using 2 axes linear interpolation

 

 

 

 

FEED-2

 

 

 

 

 

 

 

 

Axis

2,

 

500000

 

Axis used . . . .

Axis 2, Axis 3

Axis

3,

 

300000

 

Speed

 

 

10000

 

Travel value . .

Axis 2 . . .

500000

 

 

 

 

 

Axis 3

300000

 

 

 

 

 

 

 

 

 

 

 

Positioning speed . . . .

. . . . . . . .

. 10000

(Note): Example of the Motion SFC program for positioning control is shown next page.

6 - 83