6POSITIONING CONTROL

(2)Positioning operation details

The positioning is used the Axis 3 and Axis 4 servomotors.

The positioning operation by the Axis 3 and Axis 4 servomotors is shown in the diagram below.

Positioning using the servo program No.11

Axis 3 positioning

(40000, 50000)

direction

 

 

 

Axis 4 positioning

Home position (0, 0)

direction

(3)Positioning conditions

(a)Positioning conditions are shown below.

Item

Servo Program No.

No.11

 

Positioning speed

30000

(b)Positioning start command ........ Turning PX000 off to on (OFF ON)

(4)Operation timing

Operation timing for 2 axes linear interpolation control is shown below.

V

Servo program No.11

t

PLC ready flag (M2000)

All axes servo ON command (M2042)

All axes servo ON accept flag (M2049)

Axis 3 servo ready (M2455)

Axis 4 servo ready (M2475)

Start command (PX000)

Servo program start

Axis 3 start accept flag (M2003)

Axis 4 start accept flag (M2004)

6 - 25