3 POSITIONING DEDICATED SIGNALS

(8) Servo amplifier loading information (D9191 to D9192)

........... Monitor device

The installation state of the servo amplifier is checked at the power supply on or resetting of the Motion CPU and its results are stored in this device.

If communication with servo amplifier stops, it is reset.

Installation state is stored also about the axis which from non-installation to installation or from installation to non-installation after power supply on.

 

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

D9191

Axis 16

Axis 15

Axis 14

Axis 13

Axis 12

Axis 11

Axis 10

Axis 9

Axis 8

Axis 7

Axis 6

Axis 5

Axis 4

Axis 3

Axis 2

Axis 1

D9192

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis 32

Axis 31

Axis 30

Axis 29

Axis 28

Axis 27

Axis 26

Axis 25

Axis 24

Axis 23

Axis 22

Axis 21

Axis 20

Axis 19

Axis 18

Axis 17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Servo amplifier installation state

 

Installation. . . . . . . .

1

(Note): The range of axis No.1 to 8 is valid in the Q172HCPU.

Non-installation. . . .

0

(a)Servo amplifier installation state

1)Installation/non-installation state

"Installation" state ..…..... The servo amplifier is normal. (Communication with the servo amplifier is normal.)

"Non-installation" state ... No servo amplifier is installed.

The servo amplifier power is off. Normal communication with the servo amplifier is not possible due to a connecting cable fault, etc.

2)The system settings and servo amplifier installation states are shown below.

System Settings

Servo amplifier

Installation

Non-installation

 

Used (axis No. setting)

1 is stored

0 is stored

Unused

0 is stored

(9) PC link communication error codes (D9196) ........... Monitor device

When an error occurs during the PC link communication, the error code is stored in this device.

PC communication error code storage register

Contents

D9196

00: No error

01: Receiving timing error

02: CRC error

03: Communication response code error

04: Received frame error

05: Communication task start error

(Each error code is reset to "00" when normal communication is restarted.)

Refer to APPENDIX 1.5 for details of the PC link communication errors.

3 - 64