5 SERVO PROGRAMS FOR POSITIONING CONTROL

5. SERVO PROGRAMS FOR POSITIONING CONTROL

Servo programs specify the type of the positioning data required to execute the positioning control in the Multiple CPU system.

This chapter describes the configuration and setting method of the servo programs. Refer to Chapter "6 POSITIONING CONTROL" for details of the servo program.

5.1 Servo Program Composition Area

This section is described the composition of servo programs and the area in which stores the servo program.

5.1.1 Servo program composition

A servo program is composed a program No., servo instructions and positioning data. When a program No. and the required servo instructions are specified using a peripheral device, the positioning data required to execute the specified servo instructions can be set.

 

 

Program No.

 

 

 

 

 

 

 

 

 

<K 11>

 

 

 

 

Control units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Servo instruction

 

ABS-3

 

 

 

 

 

 

 

 

 

3000000.0

[mm]

 

 

 

Axis

1,

 

 

 

 

Axis

2,

 

5500000.0

[mm]

Positioning

 

 

Axis

3,

 

-2500000.0

[mm]

 

Combined speed

40000.00

[mm/min]

data

 

 

Dwell

 

 

2500

[ms]

 

 

 

M-code

 

 

12

 

 

 

 

 

P.B.

 

 

3

 

 

Number of program steps

10

Number of used programs 20/13312

[Explanation of the program]

5

K11 . . . . . . . Program No.11

 

ABS-3 . . . . . 3 axes linear interpolation control as absolute

 

 

data method.

 

Axis1,

3000000.0

. . . Axis used and positioning address

 

Axis2,

5500000.0

 

Axis3, -2500000.0

 

 

 

Used axes

Positioning address

 

 

1

3000000.0[µm]

 

 

2

5500000.0[µm]

 

 

3

-2500000.0[µm]

 

Combined speed ……… Command speed for the 3 axes (axis 1, axis 2, axis 3) combination

40000.00 [mm/min]

• Dwell ……………………. Dwell time

2500

[ms]

M-code …………………. M-code

12

 

• P.B. ……………………... Parameter block No. 3

 

Fig. 5.1 Composition example of servo program

(1)Program No. ........... This No. is specified using the Motion SFC program. Any No. in the range of 0 to 4095 can be set.

(2)Servo instruction .… Type of positioning control is indicated.

Refer to Section 5.2 for details.

5 - 1