6 POSITIONING CONTROL

[Program]

Program for repetition 1 axis fixed-pitch feed control is shown as the following conditions.

(1) System configuration

Fixed-pitch feed control of Axis 4.

Motion CPU control module

Q61P Q02H Q172H Q172 QX41

CPU CPU LX

Positioning start command (PX000)

Positioning end command (PX001)

AMP

AMP

AMP

AMP

Axis

Axis

Axis

Axis

1 M

2 M

3 M

4 M

(2)Fixed-pitch feed control conditions

(a)Positioning conditions are shown below.

Item

Setting

Servo program No.

No.300

Control axis

Axis 4

Control speed

10000

Travel value

80000

(b)Fixed-pitch feed control start command ....... Turning PX000 off to on (OFF ON)

(c)Fixed-pitch feed control end command ....…. Turning PX001 off to on (OFF ON)

6 - 78