3 POSITIONING DEDICATED SIGNALS

(17)Control loop monitor status (M2272 to M2303)............................... Command signal

When using the fully closed loop control servo amplifier, this signal is used to check the fully closed loop control/semi closed loop control of servo amplifier.

• ON .......... During fully closed loop control

• OFF .......... During semi closed loop control

It can be changed the fully closed loop control/semi closed loop control of servo amplifier in the Motion controller by the control loop changing command ON/OFF.

Fully closed loop

 

Semi closed loop

control change

ON

control change

Control loop

 

 

 

changing command OFF

 

 

(M3218+20n)

ON

 

Control loop

OFF

monitor status

 

(M2272+n)

 

The Control loop monitor status list is shown below.

Axis No.

Device No.

Axis No.

Device No.

Axis No.

Device No.

Axis No.

Device No.

1

M2272

9

M2280

17

M2288

25

M2296

2

M2273

10

M2281

18

M2289

26

M2297

3

M2274

11

M2282

19

M2290

27

M2298

4

M2275

12

M2283

20

M2291

28

M2299

5

M2276

13

M2284

21

M2292

29

M2300

6

M2277

14

M2285

22

M2293

30

M2301

7

M2278

15

M2286

23

M2294

31

M2302

8

M2279

16

M2287

24

M2295

32

M2303

(Note): The range of axis No.1 to 8 is valid in the Q172HCPU.

REMARK

It can be use in the SW6RN-SV13Q/SV22Q (Ver.00D or later).

3 - 41