3 POSITIONING DEDICATED SIGNALS

3.2.2 Control change registers

This area stores the JOG operation speed data.

Table 3.1 Data storage area for control change list

Name

Axis 1

Axis 2

Axis 3

Axis 4

Axis 5

Axis 6

Axis 7

Axis 8

 

D641, D640

D643, D642

D645, D644

D647, D646

D649, D648

D651, D650

D653, D652

D655, D654

 

Axis 9

Axis 10

Axis 11

Axis 12

Axis 13

Axis 14

Axis 15

Axis 16

JOG speed

D657, D656

D659, D658

D661, D660

D663, D662

D665, D664

D667, D666

D669, D668

D671, D670

setting

Axis 17

Axis 18

Axis 19

Axis 20

Axis 21

Axis 22

Axis 23

Axis 24

register

D673, D672

D675, D674

D677, D676

D679, D678

D681, D680

D683, D682

D685, D684

D687, D686

 

Axis 25

Axis 26

Axis 27

Axis 28

Axis 29

Axis 30

Axis 31

Axis 32

 

D689, D688

D691, D690

D693, D692

D695, D694

D697, D696

D699, D698

D701, D700

D703, D702

 

 

 

 

(Note): The range of axis No.1 to 8 is valid in the Q172HCPU.

(1)JOG speed setting registers (D640+2n) ....…….. Command device

(a)This register stores the JOG speed at the JOG operation.

(b)Setting range of the JOG speed is shown below.

Unit

mm

 

inch

 

degree

PLS

 

Item

Setting range

 

Unit

Setting range

 

Unit

Setting range

Unit(Note)

Setting range

 

Unit

JOG speed

1 to

 

10-2

1 to

 

10-3

1 to

10-3

1 to

 

[PLS/s]

600000000

 

[mm/min]

600000000

 

[inch/min]

2147483647

[degree/min]

2147483647

 

 

 

 

 

 

(Note) : When the " speed control 10 multiplier setting for degree axis" is set to "valid" in the fixed parameter, the unit is "10-2[degree/min] ".

(c)The JOG speed is the value stored in the JOG speed setting registers when the JOG start signal turns off to on.

Even if data is changed during JOG operation, JOG speed cannot be changed.

(d)Refer to Section 6.21 for details of JOG operation.