6POSITIONING CONTROL

(5)If the manual pulse generator enable flag turns on again for axis during smoothing deceleration after manual pulse generator enable flag turns off, an error [214] is set and manual pulse generator input is not enabled. Turn the manual pulse generator enable flag on after smoothing deceleration stop (after the start accept flag OFF).

(6)If another axis is set and the same manual pulse generator enable flag turns on again during smoothing deceleration after manual pulse generator enable flag turns off, the manual pulse generator input is not enabled.

At this time, the manual pulse generator axis setting error bit of the manual pulse generator axis setting error storage register (D9185 to D9187) turns on, and the manual pulse generator axis setting error flag (M9077) turns on.

Include the start accept flag OFF for specified axis in interlocks as the conditions which turn on the manual pulse generator enable flag.

[Procedure for manual pulse generator operation]

Procedure for manual pulse generator operation is shown below.

Start

Set the manual pulse generator 1- pulse input magnification

Set the manual pulse generator

Using the Motion SFC program

operation axis

 

Turn the manual pulse generator enable flag ON

Execute the positioning by

 

manual pulse generator

 

 

 

 

 

 

 

Turn the manual pulse

. . . . . . . Using the Motion SFC program

generator enable flag OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

End

 

 

 

 

 

6 - 186