6 POSITIONING CONTROL

6.21.3 Simultaneous start

Simultaneous start JOG operation for specified multiple axes.

[Control details]

(1)JOG operation continues at the JOG speed setting register value for each axis while the JOG operation simultaneous start command (M2048) turns on, and a deceleration stop is made by the M2048 OFF.

Control of acceleration/deceleration is based on the data set in the JOG operation data.

V Acceleration based on

JOG operation data JOG operation speed

Deceleration stop based on JOG operation data

JOG operation based on D710 to D713 data

D710 to D713

ON

M2048 OFF

t

(2)JOG operation axis is set in the JOG operation simultaneous start axis setting register (D710 to D713).

 

b15

 

b14

 

b13

 

b12

 

b11

 

b10

 

b9

 

b8

 

b7

 

b6

 

b5

 

b4

 

b3

 

b2

 

b1

 

b0

 

D710

Axis 16

 

Axis 15

 

Axis 14

 

Axis 13

 

Axis 12

 

Axis 11

 

Axis 10

 

Axis 9

 

Axis 8

 

Axis 7

 

Axis 6

 

Axis 5

 

Axis 4

 

Axis 3

 

Axis 2

 

Axis 1

Forward

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D711

Axis 32

 

Axis 31

 

Axis 30

 

Axis 29

 

Axis 28

 

Axis 27

 

Axis 26

 

Axis 25

 

Axis 24

 

Axis 23

 

Axis 22

 

Axis 21

 

Axis 20

 

Axis 19

 

Axis 18

 

Axis 17

rotation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOG

D712

Axis 16

 

Axis 15

 

Axis 14

 

Axis 13

 

Axis 12

 

Axis 11

 

Axis 10

 

Axis 9

 

Axis 8

 

Axis 7

 

Axis 6

 

Axis 5

 

Axis 4

 

Axis 3

 

Axis 2

 

Axis 1

Reverse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D713

Axis 32

 

Axis 31

 

Axis 30

 

Axis 29

 

Axis 28

 

Axis 27

 

Axis 26

 

Axis 25

 

Axis 24

 

Axis 23

 

Axis 22

 

Axis 21

 

Axis 20

 

Axis 19

 

Axis 18

 

Axis 17

rotation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Note-1) Set the JOG operation simultaneous start axis with 1/0.

1: Simultaneous start is executed

0: Simultaneous start is not executed (Note-2) The range of axis No.1 to 8 is valid in

the Q172HCPU.

6 - 179