3POSITIONING DEDICATED SIGNALS

(10)Operation cycle of the Motion CPU setting (D9197)

........... Monitor device

The setting operation cycle is stored in [µs] unit.

When the "Automatic setting" is set in the system setting, the operation cycle corresponding to the number of setting axes. When "0.4[ms] / 0.8[ms] / 1.7[ms] / 3.5[ms] / 7.1[ms] / 14.2[ms]" is set in the system setting, the operation cycle corresponding to each setting.

(Note): If the servo amplifiers of 9 axes or more are connected to one SSCNET system, it does not support an operation cycle of 0.4[ms]. 0.8[ms] is used as the real operation cycle, even if 0.4[ms] is set in the system setting.

(11) State of switch (D9200) ………………………….. Monitor device

The switch state of CPU is stored in the form of the following.

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

D9200

Switch state of CPU

0 : RUN

1 : STOP

2 : L.CLR

Memory card switch

Always OFF

(All setting of each digit is "0".)

No used

b8 to b12 corresponds to SW1 to SW5 of the system setting switch. (b13 to b15 : Not used)

0 : OFF

1 : ON

(12) State of LED (D9201)…………………………..…… Monitor device

It stores whether the LED of CPU is in which state in next by the following bit patterns. 0 is OFF, 1 is ON and 2 is Flicker.)

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

D9201

(Note): Indicate the following setting. 0 : OFF

1 : ON

2 : Flicker

RUN

ERROR

M.RUN

BAT.ALARM

BOOT

Not used

MODE

0 : OFF

1 : Green

2 : Orange

3 - 65