7.4 TROUBLESHOOTING GUIDE

Table 7-5

PROBLEM

PROBABLE CAUSE

POSSIBLE SOLUTION

 

 

 

Unable to call Operator 1

• Improper setting of the

• Adjust the operator extension

 

operator extension number.

number to that of the connected

 

 

PBX (see "Operator’s

 

 

Extension" in Table B-12in

 

 

B5.1 Automated Attendant

 

 

Parameters).

 

 

 

Connected terminal (RS-

• Improper connection.

• Be sure you are using a null

232C port) does not

• Improper setting of the RS-

modem cable (see 2.8

operate.

232C parameters.

TERMINAL CONNECTION).

 

 

• The terminal and VPS should

 

 

have the same parameter

 

 

settings for Baud Rate, Word

 

 

Bit Length, Parity and Stop Bit

 

 

Length (see B7.1 RS-232C

 

 

Parameters).

 

 

 

Unable to reconnect when

• Improper setting of the busy

Re-adjust the busy signal

the line is busy.

signal reconnection procedure.

reconnection procedure to that

 

 

of the connected PBX (see

 

 

"Reconnect Sequence on

 

 

Busy" in Table B-42in B7.3

 

 

PBX Interface Parameters).

 

 

 

Unable to make a no-

• Improper setting of the no-

Re-adjust the no-response

response reconnection.

response reconnection

reconnection procedure to that

 

procedure.

of the connected PBX (see

 

 

"Reconnect Sequence on No

 

 

Answer" in Table B-42 B7.3

 

 

PBX Interface Parameters).

 

 

 

Unable to generate a call

• Improper setting of sequence.

• Adjust the Call Waiting

waiting tone from the VPS.

 

sequence to that of the

 

 

connected PBX (see "Call

 

 

Waiting Sequence" in Table B-

 

 

42 in B7.3 PBX Interface

 

 

Parameters).

 

 

 

Unable to make Intercom

• Improper setting of the

• Adjust the Intercom Paging

Paging to groups.

Intercom Paging access code.

access code to that of the

 

 

connected PBX (see "Paging

 

 

Code for Group 1-16" and

 

 

"Paging Code for All Groups" in

 

 

Table B-34in B6.7 Other

 

 

Parameters).

 

 

 