Panasonic KX-TVP200 Inband Signaling Parameters, System Administration Top Menu-1-6-3-2

Models: KX-TVP200

1 380
Download 380 pages 27.55 Kb
Page 269
Image 269

B7 SYSTEM ADMINISTRATION—HARDWARE SETTINGS

Table B-42

Parameter

Value Range

Description/Function

 

(Default)

 

 

 

 

Alternate

 

The VPS performs this sequence when transferring calls

Extension

(FX)

to extensions in the Alternate Extension Group.

Transfer

 

 

 

Sequence

 

 

 

 

 

Reconnect

 

If an extension is busy, this sequence allows the VPS to

Sequence on

(FWW)

reconnect to the caller.

Busy

 

 

 

 

 

Reconnect

 

If the extension does not answer, this sequence allows the

Sequence on

(FWW)

VPS to reconnect with the caller.

No Answer

 

 

 

 

 

Reconnect

 

The VPS performs this sequence to retrieve a call placed

Sequence on

(FWW)

on hold after the extension (in the Call Screening mode)

Refuse Call

 

has refused to accept it.

 

 

 

Light-On

 

This is the dialling sequence that the VPS must perform to

Sequence for

(None)

enable the Message Waiting Lamp at an extension.

Message

 

 

 

Waiting Lamp

 

 

 

 

 

Light-Off

 

This is the dialling sequence that the VPS must perform to

Sequence for

(None)

disable the Message Waiting Lamp at an extension.

Message

 

 

 

Waiting Lamp

 

 

 

 

 

Call Waiting

(None)

The VPS carries out this sequence when performing call

Sequence

waiting if the extension being called is busy.

 

 

 

 

Release

 

The VPS performs this sequence to release call waiting.

Sequence for

(None)

 

Call Waiting

 

 

 

 

 

Inband Signaling Parameters

Use these parameters if the PBX sends touchtones to the VPS to indicate the state of a call (busy, answered, disconnected, etc.). The integration mode must be set to "Inband". If PBX type is set to a KX-T series telephone system, the Inband Signaling parameters will automatically default to the proper codes.

To access the proper menu for Inband Signaling Parameters, follow the menu path as shown:

System Administration Top Menu-1-6-3-2

The following parameters can be programmed using "0-9", "", "#", and "A-D".

Installation Manual 269

Page 269
Image 269
Panasonic KX-TVP200 installation manual Inband Signaling Parameters, System Administration Top Menu-1-6-3-2