2.1 SAFETY PRECAUTIONS

2.1.3 Environmental Requirements

The hard disk is sensitive to cold, heat, dryness, humidity, shock, vibration, and magnetic fields. Please observe the conditions specified below.

Table 2-1 Hard Disk Drive Usage Environment

Operating Temperature

: 5 °C to 40 °C

Operating Humidity

: See Graph 1 below.

Shock

: Under 5 G

Vibration

: 5 Hz to 22 Hz : 0.0042 cm displacement; double

 

amplitude,

 

1 octave per minute.

 

23 Hz to 350 Hz : Under 0.5 G

Magnetic Field

: DC : 0.6 mT

 

to 700 kHz : 0.7 T

 

700 kHz to 1.5 MHz : 3 T

 

 

Graph 1: Allowable Relative Humidity vs. Temperature

Relative Humidity (%)

100

90

80

70

60

50

40

30

20

10

0

Operating Area

5

15

25

35

45

55

(˚C)

Temperature