You may want to configure the Push Button Trigger feature and the Relay feature to operate with the same external device. For example, suppose you want the Operator to monitor and control a locked entrance door. In this scenario, you could connect the entrance doorbell to the Push Button Trigger, and the locked entrance door to the Relay I/O port. When the doorbell is pressed, the Aastralink sends a message to the Operator IP phone that someone is requesting entrance into the building. The Operator can then unlock the door by pressing the Relay softkey on the IP phone.

Use the following procedure to configure the Trigger or Relay features.

AastraLink Web UI

Step Action

1Select Configuration->System->Relay/Push Button.

2

In the “Relay Delay (seconds)” field, specify a delay time for the relay. Valid range is 1 to 99 seconds. Default is 5.